Swoboda CZ s.r.o. - Lighting for Machine Vision System for Soldering Inspection

Design and manufacturing of dome illumination for machine vision system for automated soldering inspection.

Realization: Virtual Instrumentation division

2011

Secop s.r.o. - Test stand for insepction of compressors and run-up elements

Inspection equipment for functional testing of compressors and run-up elements. Stand consists of pneumatic and electrical part. High flexibility of the power source and the measurement circuits allows configuration according to customer needs - functional testing (of compressors, run-up relais, ePTC elements, etc.) and data logging for further processing. Pneumatic parameters: compressor suction pressure measurement (0-2 bar), suction pressure control (0-2 bar), output pressure (0-20 bar), compressor displacement (200 l/min). Electrical parameters: power source selection (0-300 V AC/45-65 Hz, 0-60 V DC), resistance measurement (0-3 Mohm), current

...
2011

Schneider Electric, s.r.o. - Contactor Test Stand

Test machine for testing of electro-mechanical contactors. Performs automated tests of the mechanical and electrical tests of the contactors. Versatile fixing allows testing of various contactor types. Electrical and mechanical (contactless laser distance sensor) detection of switching. Measurement ranges 85 mA - 65 A, 25 V - 700 V. Data logging, graphical output.

Realization: Virtual Instrumentation division

2011

Edwards. s.r.o. - Software for Vacuum Pump Production and Testing Line

Development and installation of the software applications for vacuum pump production line: software for functional test station - pump firmware and parameter upload, parameter testing, vibration measurement, software for leak test, software hi-pot inspection, database application for the control, configuration and test result presentation, software for mobile PC stations used by the operators during assembly process.

Realization: Virtual Instrumentation division

2011

Schneider Electric, s.r.o. - Test source 4 kVA for contactors testing

Single-phase sinusoidal output voltage, 50 Hz or 60 Hz, with four voltage levels (5-60 V, 15-150 V, 35-350 V and 70-700 V).

Realization: Applied Electronics division

2011

Czech Railways - Uninterruptible power supply UNZ-3 (Czech Railways, 2011)

The UNZ-3 series of static backed-up power supplies for railway safety systems.

Realization: Applied Electronics division

2011

PRECHEZA a.s. - Replacing cables to the T70 transformer

Replacing cables to the T70 transformer, replacement of fan cable, supply of reactive power regulators.

2011

MERO ČR, a.s. - Replacing a complement of surge arresters incl. structures and connections to ČS Benešovice

Replacing a complement of surge arresters incl. structures and connections to ČS Benešovice.

2011

MERO ČR, a.s. - Load distribution of ČS Benešovice

Load distribution of ČS Benešovice.

2011

MERO ČR, a.s. - Adding UPS for reinforcing of objects on the Druzhba pipeline

Adding UPS for reinforcing of objects on the Druzhba pipeline - Moutnice, Rajhrad and Radostín.

2011

ArcelorMittal Ostrava - Delivery of substations, 3 controlled fan drives 1410 kW / 690 V / 1000 rpm

Delivery of substations, 3 controlled fan drives 1410 kW / 690 V / 1000 rpm in block arrangement transformer - inverter - motor. Design, supply, commissioning.

ABB drives: ACS800.
Asynchronous motors: Siemens.

Realization: Drives division + Electrical Engineering division

2011

Siemens s.r.o., závod mobility - Design and delivery of the device for measuring 25-signals

Design and delivery of the device for measuring 25-signals of circuit pressure decreases in the range of +/-8500 Pa, 7-point temperature across the ventilation circuit in the range of 0-200 °C, temperature, pressure and humidity of the ambient air, with customer SW possibility of monitoring the actual values ​​of pressure or vacuum, long-term recording, conversion of values ​​measuring air flow through nozzles.

Realization: Virtual Instrumentation division

2011

Valeo Klimasysteme GmbH - Delivery and installation of system for noise and vibration testing (2011)

Delivery and installation of system for noise and vibration testing of air conditioning during the end-of-line test.

Realization: Virtual Instrumentation division

2010

Siemens s.r.o. Závod elektromotory - Regulated power supplies for induction motor testing

Power 200 kVA, AC voltage and current power supply for induction motor testing.

Realization: Applied Electronics division

2010

Standby source into Felton power plant, Cuba

It is not redundant design (EZZT-1 30 kVA) with one inverter.

Realization: Applied Electronics division

2010

Carmeuse Slovakia, s.r.o. - Bell crusher, INDUSTART starters

Delivery of 3 pcs. INDUSTART starters for bell crusher drives with slip-ring motors 320 kW, starter type MA 350 HD.

Realization: Drives division

2010

ČEZ a.s., Teplárna Poříčí - Primary fan drives 1540 kW / 6 kV

Delivery of 2 pcs. variable speed primary fan drives 1540 kW / 6 kV. Project, supply, commissioning.

Frequency converter Siemens: Robicon Perfect Harmony.
Asynchronous motor: ABB (existing).

Realization: Drives division + Electrical Engineering division